PART OF THE NOVA PLATFORM · KAMPALA, UGANDA · MALATYA, TURKEY · GLASGOW, SCOTLAND

RCBO-Residual Current Circuit Breakers

1–60 of 1,012 products — Browse specifications below, then submit an RFQ

1,012 products
Filters
Showing 1–60 of 1,012 products
Per page: 20 40 60
Lovato RCBO, 10A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 10A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC10A030
Current Rating: 10A Number of Poles: 1P + N Trip Sensitivity: 30mA
Lovato RCBO, 10A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 10A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC10AC300
Current Rating: 10A Number of Poles: 1P+N Trip Sensitivity: 300mA
Lovato RCBO, 16A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 16A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC16AC300
Current Rating: 16A Number of Poles: 1P+N Trip Sensitivity: 300mA
Lovato RCBO, 32A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 32A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC32A300
Current Rating: 32A Number of Poles: 1P + N Trip Sensitivity: 300mA
Schneider Electric RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range
Schneider Electric Schneider Electric RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range Part: A9DA2610
Current Rating: 10A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 20A Current Rating, 1P Poles, 300mA Trip Sensitivity, Acti9 Range
Schneider Electric Schneider Electric RCBO, 20A Current Rating, 1P Poles, 300mA Trip Sensitivity, Acti9 Range Part: A9DE6620
Current Rating: 20A Number of Poles: 1 Trip Sensitivity: 300mA
Lovato RCBO, 16A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 16A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC16A300
Current Rating: 16A Number of Poles: 1P + N Trip Sensitivity: 300mA
Lovato RCBO, 16A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 16A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC16A030
Current Rating: 16A Number of Poles: 1P + N Trip Sensitivity: 30mA
Schneider Electric RCBO, 40A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
Schneider Electric Schneider Electric RCBO, 40A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range Part: A9DC3640
Current Rating: 40A Number of Poles: 1 Trip Sensitivity: 30mA
ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range
ABB ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range Part: 2CSR275180R1064 DS201 M C6 A30
Current Rating: 6A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC16AC030
Current Rating: 16A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 25A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 25A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC25AC030
Current Rating: 25A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC10AC030
Current Rating: 10A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 20A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 20A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC20A300
Current Rating: 20A Number of Poles: 1P + N Trip Sensitivity: 300mA
Lovato RCBO, 20A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 20A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC20A030
Current Rating: 20A Number of Poles: 1P + N Trip Sensitivity: 30mA
Lovato RCBO, 25A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 25A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC25A300
Current Rating: 25A Number of Poles: 1P + N Trip Sensitivity: 300mA
Lovato RCBO, 25A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 25A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC25AC300
Current Rating: 25A Number of Poles: 1P+N Trip Sensitivity: 300mA
Schneider Electric RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range
Schneider Electric Schneider Electric RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range Part: A9DA2616
Current Rating: 16A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 32A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 32A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC32AC300
Current Rating: 32A Number of Poles: 1P+N Trip Sensitivity: 300mA
ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, System Pro M Compact Range
ABB ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, System Pro M Compact Range Part: 2CSR275180R1165 DS201 M B16 A30
Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 30mA
Lovato RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC32AC030
Current Rating: 32A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 20A Current Rating, 1P Poles, 300mA Trip Sensitivity, Acti9 Range
Schneider Electric Schneider Electric RCBO, 20A Current Rating, 1P Poles, 300mA Trip Sensitivity, Acti9 Range Part: A9DE6620
Current Rating: 20A Number of Poles: 1 Trip Sensitivity: 300mA
Lovato RCBO, 10A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 10A Current Rating, 1P + N Poles, 300mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC10A300
Current Rating: 10A Number of Poles: 1P + N Trip Sensitivity: 300mA
Lovato RCBO, 32A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 32A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC32A030
Current Rating: 32A Number of Poles: 1P + N Trip Sensitivity: 30mA
Lovato RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC20AC030
Current Rating: 20A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range
Schneider Electric Schneider Electric RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, Acti9 Range Part: A9DA2616
Current Rating: 16A Number of Poles: 1P+N Trip Sensitivity: 30mA
ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR255080R1165 DS201 B16 AC30
Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 30mA
Lovato RCBO, 20A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 20A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC20AC300
Current Rating: 20A Number of Poles: 1P+N Trip Sensitivity: 300mA
Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type C, Multi 9 Range
Schneider Electric Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type C, Multi 9 Range Part: M9D11616
Current Rating: 16A Number of Poles: 1 Trip Sensitivity: 30mA
ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR275080R1165 DS201 M B16 AC30
Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 30mA
ABB RCBO, 63A Current Rating, 3P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 63A Current Rating, 3P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR273001R1634 DS203 M AC-C63/0,03
Current Rating: 63A Number of Poles: 3 Trip Sensitivity: 30mA
ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range
ABB ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range Part: 2CSR275180R1064 DS201 M C6 A30
Current Rating: 6A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 13A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 13A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC13A030
Current Rating: 13A Number of Poles: 1P + N Trip Sensitivity: 30mA
Lovato RCBO, 25A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range
Lovato Lovato RCBO, 25A Current Rating, 1P + N Poles, 30mA Trip Sensitivity, Type A, P1RE1NC Range Part: P1RE1NC25A030
Current Rating: 25A Number of Poles: 1P + N Trip Sensitivity: 30mA
ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR275080R1165 DS201 M B16 AC30
Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 30mA
ABB RCBO, 16A Current Rating, 2P Poles, 100mA Trip Sensitivity, Type B, System Pro M Compact Range
ABB ABB RCBO, 16A Current Rating, 2P Poles, 100mA Trip Sensitivity, Type B, System Pro M Compact Range Part: 2CSR255080R2165 DS201 B16 AC100
Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 100mA
Europa RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type A, EUB1RC Range
Europa Europa RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type A, EUB1RC Range Part: EUB1RC.10/1BA
Current Rating: 10A Number of Poles: 1 Trip Sensitivity: 30mA
ABB RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range
ABB ABB RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range Part: 2CSR255051R1324 DSE201 C32 AC30 - N Blue
Current Rating: 32A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 6A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
Schneider Electric Schneider Electric RCBO, 6A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range Part: A9DC3606
Current Rating: 6A Number of Poles: 1 Trip Sensitivity: 30mA
Europa RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type AC, EUC7R Range
Europa Europa RCBO, 10A Current Rating, 1P Poles, 30mA Trip Sensitivity, Type AC, EUC7R Range Part: EUC7RC.10/1CA
Current Rating: 10A Number of Poles: 1 Trip Sensitivity: 30mA
ABB RCBO, 10A Current Rating, 1P Poles, Type B
ABB ABB RCBO, 10A Current Rating, 1P Poles, Type B Part: 2CSR275151R0105
Current Rating: 10A Number of Poles: 1 Tripping Characteristics: Type B
ABB RCBO, 10A Current Rating, 1P Poles, Type C
ABB ABB RCBO, 10A Current Rating, 1P Poles, Type C Part: 2CSR275051R3104
Current Rating: 10A Number of Poles: 1 Tripping Characteristics: Type C
ABB RCBO, 10A Current Rating, 3P Poles, Type C
ABB ABB RCBO, 10A Current Rating, 3P Poles, Type C Part: 2CSR253001R1104
Current Rating: 10A Number of Poles: 3 Tripping Characteristics: Type C
ABB RCBO, 20A Current Rating, 2P Poles, Type B
ABB ABB RCBO, 20A Current Rating, 2P Poles, Type B Part: 2CSR272001R1205
Current Rating: 20A Number of Poles: 2 Tripping Characteristics: Type B
ABB RCBO, 20A Current Rating, 2P Poles, Type C
ABB ABB RCBO, 20A Current Rating, 2P Poles, Type C Part: 2CSR252001R1204
Current Rating: 20A Number of Poles: 2 Tripping Characteristics: Type C
ABB RCBO, 10A Current Rating, 4P Poles, Type B
ABB ABB RCBO, 10A Current Rating, 4P Poles, Type B Part: 2CSR274001R1105
Current Rating: 10A Number of Poles: 4 Tripping Characteristics: Type B
ABB RCBO, 20A Current Rating, 4P Poles, Type B
ABB ABB RCBO, 20A Current Rating, 4P Poles, Type B Part: 2CSR254101R1205
Current Rating: 20A Number of Poles: 4 Tripping Characteristics: Type B
ABB RCBO, 13A Current Rating, 3P Poles, Type C
ABB ABB RCBO, 13A Current Rating, 3P Poles, Type C Part: 2CSR253101R1134
Current Rating: 13A Number of Poles: 3 Tripping Characteristics: Type C
ABB RCBO, 25A Current Rating, 2P Poles, Type B
ABB ABB RCBO, 25A Current Rating, 2P Poles, Type B Part: 2CSR272001R1255
Current Rating: 25A Number of Poles: 2 Tripping Characteristics: Type B
ABB RCBO, 25A Current Rating, 3P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 25A Current Rating, 3P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR273001R1254 DS203 M AC-C25/0,03
Current Rating: 25A Number of Poles: 3 Trip Sensitivity: 30mA
ABB RCBO, 32A Current Rating, 2P Poles, 300mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 32A Current Rating, 2P Poles, 300mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR255080R3324 DS201 C32 AC300
Current Rating: 32A Number of Poles: 2 Trip Sensitivity: 300mA
Schneider Electric RCBO, 16A Current Rating, 4P Poles, 30mA Trip Sensitivity, Type AC, Acti9 Range
Schneider Electric Schneider Electric RCBO, 16A Current Rating, 4P Poles, 30mA Trip Sensitivity, Type AC, Acti9 Range Part: A9D57416
Current Rating: 16A Number of Poles: 4 Trip Sensitivity: 30mA
Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range
Schneider Electric Schneider Electric RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, Acti9 Range Part: A9DC3616
Current Rating: 16A Number of Poles: 1 Trip Sensitivity: 30mA
ABB RCBO, 20A Current Rating, 3P Poles, Type B
ABB ABB RCBO, 20A Current Rating, 3P Poles, Type B Part: 2CSR253001R1205
Current Rating: 20A Number of Poles: 3 Tripping Characteristics: Type B
ABB RCBO, 20A Current Rating, 4P Poles, Type B
ABB ABB RCBO, 20A Current Rating, 4P Poles, Type B Part: 2CSR274001R1205
Current Rating: 20A Number of Poles: 4 Tripping Characteristics: Type B
ABB RCBO, 16A Current Rating, 1P Poles, Type C
ABB ABB RCBO, 16A Current Rating, 1P Poles, Type C Part: 2CSR275151R3164
Current Rating: 16A Number of Poles: 1 Tripping Characteristics: Type C
ABB RCBO, 32A Current Rating, 3P Poles, Type B
ABB ABB RCBO, 32A Current Rating, 3P Poles, Type B Part: 2CSR253001R1325
Current Rating: 32A Number of Poles: 3 Tripping Characteristics: Type B
Lovato RCBO, 40A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 40A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC40AC300
Current Rating: 40A Number of Poles: 1P+N Trip Sensitivity: 300mA
ABB RCBO, 10A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
ABB ABB RCBO, 10A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range Part: 2CSR255080R1105 DS201 B10 AC30
Current Rating: 10A Number of Poles: 2 Trip Sensitivity: 30mA
Lovato RCBO, 6A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range
Lovato Lovato RCBO, 6A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C, P1 Range Part: P1RE1NC06AC300
Current Rating: 6A Number of Poles: 1P+N Trip Sensitivity: 300mA
RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue
Search