| Output Signal | 4-20 mA / Vs = 8-32 Vdc |
| Accuracy | ± 0.5% FSO IEC 60770 |
| Permissible Load | Rmax = [(Vs - Vs min) / 0.02] Ohm |
| Supply | 0.05% FSO / 10 V |
| Load | 0.05% FSO / kOhm |
| Response Time | <10 ms |
| In Compensated Range | -13°F to 185°F (-25°C to 85°C) |
| Medium | -40°F to 257°F (-40°C to 125°C) |
| Electronics Environment | -13°F to 185°F (-25°C to 85°C) |
| Storage | -40°F to 212°F (-40°C to 100°C) |
| Short Circuit Protection | Permanent |
| Reverse Polarity Protection | No damage - No function |
| Electromagnetic Protection | Emission and immunity according to EN 61326 |
| I.S. Protection | Class 1, Div. 1, Groups A, B, C & D |
| Vibration | 10 g RMS (20 to 2,000 Hz) |
| Shock | 500 g / 1 ms |
| Polluiton Degree | 4, electrical equipment for outdoor use |
| Housing | 316L Stainless Steel |
| Pressure Port | 316 L Stainless Steel |
| Seals | PN < 1450 psi: FKM70 |
Appropriate for all hazardous areas where an intrinsically safe rating is required, including oil & gas and chemical installations. Features Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas Rugged stainless steel construction with ceramic sensor Available ranges include in/Hg up to 8,700 psi Wide range of mechanical and electrical connections ±0.5% FSO accuracy NEMA 4X and 6P / IP65, IP67 or IP68 Approved for outdoor use Customizable 5 year warranty Specifications Output Signal: 4-20 mA / Vs = 8-32 Vdc Accuracy: ± 0.5% FSO IEC 60770 Permissible Load: Rmax = [(Vs - Vs min) / 0.02] Ohm Influence Effects: Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm Response Time: <10 ms Thermal Error: <±0.2% FSO / 10K In Compensated Range: -13°F to 185°F (-25°C to 85°C) Permissible Temperatures: Medium: -40°F to 257°F (-40°C to 125°C) Electronics Environment: -13°F to 185°F (-25°C to 85°C) Storage: -40°F to 212°F (-40°C to 100°C) Short Circuit Protection: Permanent Reverse Polarity Protection: No damage - No function Electromagnetic Protection: Emission and immunity according to EN 61326 I.S. Protection: Class 1, Div. 1, Groups A, B, C & D Stability: Vibration: 10 g RMS (20 to 2,000 Hz) Shock: 500 g / 1 ms Polluiton Degree: 4, electrical equipment for outdoor use Housing: 316L Stainless Steel Pressure Port: 316 L Stainless Steel Wetted Parts: Seals: PN < 1450 psi: FKM70 Diaphragm: Ceramic AI2O3 96% Weight: 140 g Current Consumption: Current: 25mA max Voltage: 7 mA max Operating Life: >100 x 10^6 Cycles Connecting Cables: Cable Capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable Inductance: Signal line/shield and signal line/signal line: 1 uH/m Downloads LIS Series Pressure Transmitter Technical Drawing (PDF Download)