Regenerative Air Blowers
41–57 of 57 products — Browse specifications below, then submit an RFQ
Filters
All Star
All Star Regenerative Air Blowers; Inlet Size: 2"; Outlet Size: 2"; Horse Power: 5.0; Amperage Rating: 14.9000; Cubic Feet Per Minute: 228 SCFM; Height (Inch): 17; Width (Decimal Inch): 17; Maximum Working Water Pressure: 119.00; Maximum Vacuum Water Pressure: 112.00; Overall Length: 17.00; Phase: 3-
Part: RBH6-5-3
Inlet Size: 2"
Outlet Size: 2"
Horse Power: 5.0
All Star
All Star Regenerative Air Blowers; Inlet Size: 1.5"; Outlet Size: 1.5"; Horse Power: 2.0; Amperage Rating: 5.7000; Cubic Feet Per Minute: 105 SCFM; Height (Inch): 14; Width (Decimal Inch): 14; Maximum Working Water Pressure: 90.00; Maximum Vacuum Water Pressure: 82.00; Overall Length: 14.00; Phase: 3-
Part: RBH3-2-3
Inlet Size: 1.5"
Outlet Size: 1.5"
Horse Power: 2.0
All Star
All Star 3 Phase 5 hp 1,725 SCFM 7" Non-Threaded Inlet 6" Non-Threaded Outlet Turbo Air Blower-14.9 Amps, 15.7 Max Working psi, 27" OAL x 26" OAW x 31" OAH
Part: TB5-3
Inlet Size: 7" Non-Threaded
Outlet Size: 6" Non-Threaded
Horse Power: 5.0
Gast
Gast 1 HP Single Phase Regenerative Air Blower-115/230V, 92 Max CFM, 52" Max Water Pressure, 48" Max Vacuum Water Pressure, 9.8/4.9 Full Load Amps G3289913
Part: R4110-2
Inlet Size: 1.5 in
Outlet Size: 1.50 in
Horse Power: 1 hp; 1 W; 1 h; 1 hp old
All Star
All Star Regenerative Air Blowers; Inlet Size: 2"; Outlet Size: 2"; Horse Power: 6.1; Amperage Rating: 17.6000; Cubic Feet Per Minute: 230 SCFM; Height (Inch): 23; Width (Decimal Inch): 23; Maximum Working Water Pressure: 153.00; Maximum Vacuum Water Pressure: 153.00; Overall Length: 24.00; Phase: 3-
Part: RBH43-601-3
Inlet Size: 2"
Outlet Size: 2"
Horse Power: 6.1
All Star
All Star Regenerative Air Blowers; Inlet Size: 2"; Outlet Size: 2"; Horse Power: 6.1; Amperage Rating: 17.6000; Cubic Feet Per Minute: 228 SCFM; Height (Inch): 17; Width (Decimal Inch): 17; Maximum Working Water Pressure: 129.00; Maximum Vacuum Water Pressure: 125.00; Overall Length: 17.00; Phase: 3-
Part: RBH6-601-3
Inlet Size: 2"
Outlet Size: 2"
Horse Power: 6.1
All Star
All Star 3 Phase 3.5 hp 1,400 SCFM 6" Non-Threaded Inlet 5" Non-Threaded Outlet Turbo Air Blower-10.5 Amps, 15 Max Working psi, 24" OAL x 23" OAW x 24" OAH
Part: TB305-3
Inlet Size: 6" Non-Threaded
Outlet Size: 5" Non-Threaded
Horse Power: 3.5
Gast
Gast Regenerative Air Blowers; Inlet Size: 2 in; Outlet Size: 2 in; Amperage Rating: 50 A, 50 mA; Maximum Working Water Pressure: 105.0; Maximum Vacuum Water Pressure: 88.0-
Part: R6335A-2
Inlet Size: 2 in
Outlet Size: 2 in
Amperage Rating: 50 A; 50 mA
All Star
All Star Regenerative Air Blowers; Inlet Size: 2"; Outlet Size: 2"; Horse Power: 3.5; Amperage Rating: 21.6000; Cubic Feet Per Minute: 165 SCFM; Height (Inch): 23; Width (Decimal Inch): 24; Maximum Working Water Pressure: 155.00; Maximum Vacuum Water Pressure: 155.00; Overall Length: 24.00; Phase: 1-
Part: RBH43-305-2
Inlet Size: 2"
Outlet Size: 2"
Horse Power: 3.5
All Star
All Star 1 Phase .5 hp 675 SCFM 4" Non-Threaded Inlet 3" Non-Threaded Outlet Turbo Air Blower-5.8 Amps, 10.4 Max Working psi, 18" OAL x 18" OAW x 18" OAH
Part: TB05-1
Inlet Size: 4" Non-Threaded
Outlet Size: 3" Non-Threaded
Horse Power: .5
All Star
All Star Regenerative Air Blowers; Inlet Size: 1.5"; Outlet Size: 1.5"; Horse Power: 1.1; Amperage Rating: 4.0000; Cubic Feet Per Minute: 105 SCFM; Height (Inch): 14; Width (Decimal Inch): 14; Maximum Working Water Pressure: 58.00; Maximum Vacuum Water Pressure: 59.00; Overall Length: 14.00; Phase: 3-
Part: RBH3-101-3
Inlet Size: 1.5"
Outlet Size: 1.5"
Horse Power: 1.1
Gast
Gast Regenerative Air Blowers; Inlet Size: 1.5 in; Outlet Size: 1.50 in; Amperage Rating: 18.5 mA, 18.5 A; Maximum Working Water Pressure: 65.0; Maximum Vacuum Water Pressure: 60.0-
Part: R4P315A
Inlet Size: 1.5 in
Outlet Size: 1.50 in
Amperage Rating: 18.5 mA; 18.5 A
All Star
All Star Regenerative Air Blowers; Inlet Size: 1.5"; Outlet Size: 1.5"; Horse Power: 2.5; Amperage Rating: 7.7000; Cubic Feet Per Minute: 105 SCFM; Height (Inch): 15; Width (Decimal Inch): 20; Maximum Working Water Pressure: 118.00; Maximum Vacuum Water Pressure: 120.00; Overall Length: 20.00; Phase: 3-
Part: RBH33-205-3
Inlet Size: 1.5"
Outlet Size: 1.5"
Horse Power: 2.5
All Star
All Star Regenerative Air Blowers; Inlet Size: 2.5; Outlet Size: 2.5; Horse Power: 25; Amperage Rating: 75.0000; Cubic Feet Per Minute: 410 SCFM; Height (Inch): 28; Width (Decimal Inch): 30; Maximum Working Water Pressure: 317.00; Maximum Vacuum Water Pressure: 261.00; Overall Length: 38.00; Phase: 3-
Part: RBH83-25-3
Inlet Size: 2.5
Outlet Size: 2.5
Horse Power: 25
All Star
All Star Regenerative Air Blowers; Inlet Size: 2"; Outlet Size: 2"; Horse Power: 8.50; Amperage Rating: 28.6000; Cubic Feet Per Minute: 230 SCFM; Height (Inch): 22; Width (Decimal Inch): 25; Maximum Working Water Pressure: 217.00; Maximum Vacuum Water Pressure: 171.00; Overall Length: 28.00; Phase: 3-
Part: RBH63-805-3
Inlet Size: 2"
Outlet Size: 2"
Horse Power: 8.50
All Star
All Star 3 Phase 1.1 hp 675 SCFM 5" Non-Threaded Inlet 4" Non-Threaded Outlet Turbo Air Blower-4 Amps, 10.4 Max Working psi, 20" OAL x 19" OAW x 20" OAH
Part: TB1-3
Inlet Size: 5" Non-Threaded
Outlet Size: 4" Non-Threaded
Horse Power: 1.1
All Star
All Star Regenerative Air Blowers; Inlet Size: 1"; Outlet Size: 1"; Horse Power: .33; Amperage Rating: 1.2000; Cubic Feet Per Minute: 38 SCFM; Height (Inch): 10; Width (Decimal Inch): 9; Maximum Working Water Pressure: 32.00; Maximum Vacuum Water Pressure: 30.00; Overall Length: 10.00; Phase: 3-
Part: RB1-033-3
Inlet Size: 1"
Outlet Size: 1"
Horse Power: .33